Document Type
Article
Rights
Available under a Creative Commons Attribution Non-Commercial Share Alike 4.0 International Licence
Abstract
A compact temperature sensor based on a broadband microfiber coupler tip is demonstrated. The thermometer dynamic range spans from room temperature to 1511 with a response time of tens of milliseconds. This is the highest temperature measured with a silica optical fiber device. A resolution of 0.66 was achieved for a coupler tip diameter of . Better resolution can be achieved with smaller sized microfiber coupler tips.
DOI
https://doi.org/10.1109/LPT.2012.2200673
Recommended Citation
Ding, M., Wang, P., & Brambilla, G. (2012) Fast-Response High-Temperature Microfiber Coupler Tip Thermometer. Photonics Technology Letters, IEEE , vol.24, no.14, pp.1209,1211, 15 July. doi:10.1109/LPT.2012.2200673
Publication Details
Photonics Technology Letters, IEEE , vol.24, no.14, pp.1209,1211, July15, 2012
doi: 10.1109/LPT.2012.2200673