Document Type

Article

Disciplines

1.3 PHYSICAL SCIENCES

Publication Details

https://www.sciencedirect.com/science/article/pii/S0889157523005239

H. Alwael, S.H. Al-Sedran, M. Oubaha, N.A.A. Asiri, A.S. Bashammakh, A.S. Alharthy, N.A. Albassami, T.N. Abduljabbar, G.I. Mohammed, H.M. Nassef, E.A. Bahaidarah, B.G. Alhogbi, M.S. El-Shahawi, Probe –integrated electrochemical sensing platform for measuring trace levels of parathion pesticides residues in water using Au- nanoparticles anchored Nafion nano composite modified glassy carbon electrode, Journal of Food Composition and Analysis, Volume 124, 2023, 105649, ISSN 0889-1575,

https://doi.org/10.1016/j.jfca.2023.105649.

Abstract

Nanomaterial represents a principal driver to the adoption of electrochemical sensors for pesticides residues in water. Thus, the current strategy reports facile and highly sensitive electrochemical probe for monitoring parathion residues in water. The probe was based upon the use of Au nanoparticles (AuNPs) functionalized Nafion nanocomposites modified glassy carbon electrode (Au NPs/Nafion/GCE). The surface morphology, effective surface area and electrocatalytic performance of the Au NPs/Nafion/GCE were recorded and assigned using a scanning electron microscopy (SEM), cyclic voltammetry (CV) and electronic spectra. A straightforward protocol based upon combination of Au NPs/Nafion/GCE and square wave- adsorptive cathodic stripping voltammetry at pH 7.0 was established for parathion detection. The probe displayed two linear responses between the catholic peak current (ip,c) at 􀀀 0.8 V versus parathion concentrations over the ranges from 1.07 × 10􀀀 6 - 1.07 × 10􀀀 5 and 1.99 × 10􀀀 9 - 9.0 × 10􀀀 7 M with limits of detection (LOD) and quantification (LOQ) of 6.06 × 10􀀀 10 M and 2.0 × 10􀀀 9 M, respectively. The probe exhibited excellent reproducibility, repeatability with RSD of ± 0.5% (n = 5) at 8.0 × 10􀀀 7 M parathion. The probe was applied for parathion detection in water and validated by HPLC. The experimental Student texp and Fexp values were less than the tabulated ttab (2.78) and Ftab (6.39) at 95% probability.

DOI

https://doi.org/10.1016/j.jfca.2023.105649

Funder

This project was funded by the National Plan for Science, Technology and Innovation (MAARIFAH)-King Abdulaziz City for Science and Technol-the Kingdom of Saudi Arabia-award number (UE-41-114).

Creative Commons License

Creative Commons Attribution-Share Alike 4.0 International License
This work is licensed under a Creative Commons Attribution-Share Alike 4.0 International License.

Available for download on Wednesday, January 08, 2025


Included in

Chemistry Commons

Share

COinS