Document Type
Article
Rights
Available under a Creative Commons Attribution Non-Commercial Share Alike 4.0 International Licence
Disciplines
3. MEDICAL AND HEALTH SCIENCES
Abstract
Changes in protein concentrations within human blood are used as an indicator for nutritional state, hydration and underlying illnesses. They are often measured at regular clinical appointments and the current analytical process can result in long waiting times for results and the need for return patient visits. Attenuated total reflectance – Fourier transform infrared (ATR-FTIR) spectroscopy has the ability to detect minor molecular differences, qualitatively and quantitatively, in biofluid samples, without extensive sample preparation. ATR-FTIR can return an analytical measurement almost instantaneously and therefore could be deemed as an ideal technique for monitoring molecular alterations in blood within the clinic. To determine the suitability of using ATR-FTIR spectroscopy to enable protein quantification in a clinical setting, pooled human serum samples spiked with varying concentrations of human serum albumin (HSA) and immunoglobulin G (IgG) were analysed, before analysing patient clinical samples. Using a validated partial least squares method, the spiked samples (IgG) produced a linearity as high as 0.998 and a RMSEV of 0.49 ± 0.05 mg mL−1, with the patient samples producing R2 values of 0.992 and a corresponding RMSEV of 0.66 ± 0.05 mg mL−1. This claim was validated using two blind testing models, leave one patient out cross validation and k-fold cross validation, achieving optimum linearity and RMSEV values of 0.934 and 1.99 ± 0.79 mg mL−1, respectively. This demonstrates that ATR-FTIR is able to quantify protein within clinically relevant complex matrices and concentrations, such as serum samples, rapidly and with simple sample preparation. The ability to provide a quantification step, along with rapid disease classification, from a spectroscopic signature will aid clinical translation of vibrational spectroscopy to assist with problems currently faced with patient diagnostic pathways.
DOI
https://doi.org/10.1016/j.vibspec.2018.08.019
Recommended Citation
Spalding, K., Bonnier, F. & Bruno, C. (2018). Enabling quantification of protein concentration in human serum biopsies using attenuated total reflectance _ Fourier transform infrared (ATR-FTIR) spectroscopy. Vibrational Spectroscopy, vol. 99. pg. 50-58. doi:10.1016/j.vibspec.2018.08.019
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 International License.
Publication Details
Vibrational Spectroscopy
Volume 99, November 2018, Pages 50-58